https://www.rechner-sensors.com/wp-content/uploads/2016/11/water_drops_products_bg.jpg

KAS-40-A14-IL20-StEx, ATEX

Out of stock

SKU: KA1394 Category:
Data sheet: Download PDF

Description

Capacitive sensors with 4…20 mA or 20…4 mA output signal.
For level control or position control in areas with risk of explosion,
ATEX Zone 0 (Gas) and 20 (Dust).

Analogue

ATEX Zone 0 Zone 20

Namur

Additional information

Thread / Process connection

M 30 x 1,5

Housing material active surface

PTFE (FDA 21 CFR 177.1550)

Housing material

Messing

Electrical version

2-Leiter DC

Permitted residual ripple max.

5%

Protective circuit

Eingebaut

Degree of protection IEC 60529

IP 67 (mit versiegelter Potentiometerschraube)

Norm

EN 60947-5-6, EN 60947-5-7

Selfinductance (L)

0,2 mH

Selfcapacitance (C)

89 nF

Operating current active surface free

≥ 20 mA

Operating current active surface covered

≤ 4 mA

Load resistance (RL)

≤ 500 Ω

Linear range

0…12 mm

Operating range

0…20 mm

Operating voltage

15…35 V DC, Ui = 27 V DC

Permitted ambient temperature min.

-20 °C

Permitted ambient temperature max.

+70 °C

Installation

Bündig

Output function

NAMUR / Analog

Output signal

20 – 4 mA

Cable length

2 m

Connection

PVC-Kabel, 3 x 0,75 mm²

CE

JA

RoHS

JA

UL CSA certification

JA

ATEX product marking dust

Ex II 1D Ex ia Ex IIIC T 101°C Da

ATEX product marking gas

Ex II 1G Ex ia Ex IIC T1 – T6 Ga

Certified Zones ATEX

1G1D

IECEX product marking dust

Ex ia IIIC T101° Da

IECEX product marking gas

Ex ia IIC T1 – T6 Ga

MTTF

1060,35 Jahre

WHG certification

Auf Anfrage

Highlights 2020 product overview Download PDF
Capacitive Sensors Download PDF
Capacitive sensors
UL/CSA Download PDF
ATEX (No. 1) Download PDF