KAS-80-A14-A-M30-PBT-Y3-1-NL-3G-3D, ATEX

SKU: KA1566 Category:

3D-Zeichnung: Download PDF
3D-Zeichnung: STP herunterladen

Additional information

Thread / Process connection

M 30 x 1,5

Housing material active surface

PPO

Housing material

PA / PPO

Housing material lid

PA

Electrical version

4-Leiter DC

Operating current (Ie)

2 x 0…150 mA

Voltage drop max. (Ud)

≤ 2 V

Permitted residual ripple max.

5%

Noload current (Io)

< 15 mA

Frequency of operating cycles max.

150 Hz

LEDAnzeige

Gelb

Protective circuit

Eingebaut

Degree of protection IEC 60529

IP 67 (mit versiegelter Potentiometerschraube)

Norm

EN 60947-5-2

Sensing dinstance Sn

10 mm

Operating distance min. / max. adjustable

2…20 mm

Operating voltage

12…30 V DC

Permitted ambient temperature min.

-25 °C

Zulässige Umgebungstemperatur max.

+70 °C

Installation

Bündig

Output function

Antivalent (S + Ö)

Output signal

PNP

Anschluss

Steckerflansch M 12 x 1

CE

JA

RoHS

[:de]JA[:en]JA[:fr]JA[:es]JA[:it]JA[:]

ATEX product marking dust

Ex II 3D IP67 T101° C X

ATEX product marking gas

Ex II 3G EEx nA Ex II T6 X,

Certified Zones ATEX

3G3D

MTTF

2714,31 Jahre

WHG certification

Auf Anfrage