https://www.rechner-sensors.com/wp-content/uploads/2016/11/water_drops_products_bg.jpg

N-132/2/4-20-IL, ATEX

Ex II 3 (1) G Ex nA nC [ia] IIC T4, Ex II (1) D [Ex iaD]

40 in stock

Data sheet: Download PDF

Description

Transmitter Power Supply
N-132/2/4-20-IL – Analogue Output 4…20 mA
• For connection of 2 ATEX certified 2-wire analogue sensors e. g. our
KAS-40…IL with 4…20 mA output signal
• Transmitter for use in areas with the risk of gas explosion, zone 2
• Galvanic isolation between input, output and power supply
• Compact design – only 17.6 mm width
• Removable screw terminals
• Indication sensor wire-break or shortcircuit via relay contact

 

DMT 09 ATEX E 129X IECEx BVS 10.0087X
II 3(1)G Ex nA nC [ia Ga] IIC T4 Gc Ex nA nC [ia Ga] IIC T4 Gc
II (1)D [Ex ia Da] IIIC [Ex ia Da] IIIC

Additional information

Thread / Process connection

114,5 x 108 x 17,6 mm

Housing material

PA

Noload current (Io)

Typ. 125 mA

LEDdisplay

Grün / Gelb / Rot

Degree of protection IEC 60529

IP 30, IP20

Norm

EN 60947-5-6

Operating voltage

24 V DC

Permitted ambient temperature min.

-20 °C

Permitted ambient temperature max.

+70 °C

Output function

2 x potenzialfreier Wechsler

Connection

Schraubklemmen

CE

JA

RoHS

JA

ATEX product marking dust

Ex II (1) D [Ex iaD]

ATEX product marking gas

Ex II 3 (1) G Ex nA nC [ia] Ex IIC T4

Certified Zones ATEX

3G1D

IECEX product marking dust

[Ex ia Da] IIIC

IECEX product marking gas

Ex nA nC [ia Ga] IIC T4 Gc

MTTF

Auf Anfrage

WHG certification

Auf Anfrage

Transmitter Power Supply
ATEX – N-132…IL 2019 Download PDF
Transmitter Power Supply
ATEX – N-132…IL Download PDF

Available accessories