https://www.rechner-sensors.com/wp-content/uploads/2016/11/water_drops_products_bg.jpg

KAS-80-35-A-K-M32-PTFE-StEx, ATEX

Ex II 1/2 D Ex ta/tb IIIC T101°C Da/Db; Ex II 2 G Ex mb IIC T4 Gb

SKU: KA0093 Category:
Data sheet: Download PDF

Description

Capacitive Sensors Series 80 – PNP – StEx – ATEX
Housing M 32 x 1.5
• For use in areas with the risk of dust explosion, zone 20
• For use in areas with the risk of gas explosion, zone 1
• Housing material: PTFE
• Sensing distance 3…30 mm adjustable

 

DMT 01 ATEX E 157 IECEx BVS 07.0015
II 2 G Ex mb IIC T4 Gb Ex mb IIC T4 Gb
II 1/2 D Ex ta/tb IIIC T101°C Da/Db Ex ta/tb IIIC T101°C Da/Db

Additional information

Thread / Process connection

M 32 x 1,5

Housing material active surface

PTFE (FDA 21 CFR 177.1550)

Housing material

PTFE (FDA 21 CFR 177.1550)

Housing material lid

PA / PPO

Electrical version

4-Leiter DC

Operating current (Ie)

2 x 0…150 mA

Voltage drop max. (Ud)

≤ 2 V

Permitted residual ripple max.

10%

Noload current (Io)

Typ. 15 mA

Frequency of operating cycles max.

50 Hz

LEDdisplay

Grün / Gelb

Protective circuit

Eingebaut

Degree of protection IEC 60529

IP 67 (mit versiegelter Potentiometerschraube)

Norm

EN 60947-5-2

Media optimized

JA

Quattro Protect

JA

Sensing dinstance Sn

25 mm

Operating distance min. / max. adjustable

1…40 mm

Operating voltage

10…30 V DC

Permitted ambient temperature min.

-20 °C

Permitted ambient temperature max.

+70 °C

Installation

Nichtbündig

Output function

Antivalent (S + Ö)

Output signal

PNP

Cable length

3 m

Connection

PVC-Kabel, 4 x 0,5 mm²

CE

JA

RoHS

JA

UL CSA certification

JA

ATEX product marking dust

Ex II 1/2 D Ex ta/tb Ex IIIC T101°C Da/Db

ATEX product marking gas

Ex II 2G Ex mb Ex IIC T4 Gb

Certified Zones ATEX

2G1/2D

IECEX product marking dust

Ex ta/tb IIIC T101°C Da/Db

IECEX product marking gas

Ex mb IIC T4 Gb

MTTF

786,6 Jahre

WHG certification

Auf Anfrage

Capacitive Sensors Download PDF