https://www.rechner-sensors.com/wp-content/uploads/2016/11/water_drops_products_bg.jpg

KAS-80-26-A-K-G1″-PTFE-StEx, ATEX, 5 m

Ex II 1/2 D Ex ta/tb IIIC T101°C Da/Db; Ex II 2 G Ex mb IIC T4 Gb

2 in stock

SKU: KA0837 Category:
Data sheet: Download PDF

Description

Capacitive sensors
Series 80 – PNP – StEx – ATEX
Housing G 1”
• For use in areas with the risk of dust explosion, zone 20
• For use in areas with the risk of gas explosion, zone 1
• Housing material PTFE
• Special version with flange. Sealing can be made with a gasket or PTFEtape
(not supplied with the sensor)

DMT 01 ATEX E 157 IECEx BVS 07.0015
II 2 G Ex mb IIC T4 Gb Ex mb IIC T4 Gb
II 1/2 D Ex ta/tb IIIC T101°C Da/Db Ex ta/tb IIIC T101°C Da/Db

Additional information

Thread / Process connection

G 1"

Housing material active surface

PTFE (FDA 21 CFR 177.1550)

Housing material

PTFE (FDA 21 CFR 177.1550)

Housing material lid

PC (FDA 21 CFR 177.1580)

Electrical version

4-Leiter DC

Operating current (Ie)

2 x 0…150 mA

Voltage drop max. (Ud)

≤ 2 V

Permitted residual ripple max.

10%

Noload current (Io)

Typ. 15 mA

Frequency of operating cycles max.

50 Hz

LEDdisplay

Grün / Gelb

Protective circuit

Eingebaut

Degree of protection IEC 60529

IP 67 (mit versiegelter Potentiometerschraube)

Norm

EN 60947-5-2

Media optimized

JA

Quattro Protect

JA

Sensing dinstance Sn

produktberuehrend-mediumabhaengig-einstellbar

Operating distance min. / max. adjustable

0…20 mm

Operating voltage

10…30 V DC

Permitted ambient temperature min.

-20 °C

Permitted ambient temperature max.

+90 °C

CIP / SIP

CIP / SIP 121°C

Installation

Nichtbündig

Output function

Antivalent (S + Ö)

Output signal

PNP

Cable length

5 m

Connection

PVC-Kabel, 4 x 0,5 mm²

CE

JA

RoHS

JA

UL CSA certification

JA

ATEX product marking dust

Ex II 1/2 D Ex ta/tb Ex IIIC T101°C Da/Db

ATEX product marking gas

Ex II 2G Ex mb Ex IIC T4 Gb

Certified Zones ATEX

2G1/2D

IECEX product marking dust

Ex ta/tb IIIC T101°C Da/Db

IECEX product marking gas

Ex mb IIC T4 Gb

MTTF

272,63 Jahre

WHG certification

Auf Anfrage

Capacitive Sensors
S26
(semispherical active surface) Download PDF
Capacitive sensors
UL/CSA Download PDF
ATEX (No. 1) Download PDF